PE2G-Golden-Extended
Made in UAE
Lasting quality and durability
2-10 sec Delay Timer
Smart timer algorithm inside
Smart Chip
Delivering 7 types of power protection
Preventing Fire Incidents
Keeping you and your loved ones safe
Meet Powermatic
Micro Automation Industries developed Powermatic, the new concept in power protection, it connects load only after a comprehensive monitoring of electrical supply and when the supply is within the specified parameters. It continues monitoring and disconnects when there are any disturbances, thus it avoids expensive damage and breakdown to connected equipment.
Powermatic, as a microprocessor embedded solution, provides the smartest comprehensive detection and reaction response to more than one power disturbances at low cost.
Powermatic, as a microprocessor embedded solution, provides the smartest comprehensive detection and reaction response to more than one power disturbances at low cost.
Working Principle
After the main power supply (Mains) is switched ON, Powermatic will monitor the Mains and withhold it from reaching the connected equipment. If the Mains is stable (Yellow state), Powermatic continues to monitor the power quality for a certain determined time.
If the power quality is within the limits, Powermatic will then connect Mains to the equipment (Green state). However, Powermatic will continue to monitor power quality.
Powermatic disconnects whenever it detects power disturbances beyond preset limits (Red state).
When Mains resumes stable, Powermatic continues monitoring the power quality and reconnects Mains to the equipment after determined time.
If the power quality is within the limits, Powermatic will then connect Mains to the equipment (Green state). However, Powermatic will continue to monitor power quality.
Powermatic disconnects whenever it detects power disturbances beyond preset limits (Red state).
When Mains resumes stable, Powermatic continues monitoring the power quality and reconnects Mains to the equipment after determined time.
STOPS 7 TYPES
OF POWER DISTURBANCES
Built to a Sustainable Solution
Product Specifications
Type | PE2G-25 | PE2G-26 |
---|---|---|
Power Standard | 230V ~ 50Hz | 220V ~ 60Hz |
Socket Type | UK | |
No. of Sockets | 2 Sockets | |
Max. Load Current | 13 Amp | |
Waiting Time | 10 sec. | |
Over Voltage Connect | 255V | |
Under Voltage Connect | 180V | |
Interruption Response Time | 20 millisec. | |
Under Frequency | 46Hz | 56Hz |
Over Frequency | 54Hz | 64Hz |
Max. Supply | 420V | |
Inrush Current | 50A | |
Surge Response Time | <10ns | |
Surge Clamping Voltage | 1120@25 Ampere(8/20 µs surge) | |
Max. Ambient Temperature | 55°C | |
Connection Type | Direct Plug-in | |
Unit Weight | 510 gm | |
Unit Dimension(H x W x D) | 167 x 46 x 25mm | |
Cable Length | 3 meter, 5 meter | |
Packing Option | Blister Shell(BS) |